Helpline

External Wall Insulation

1.1 Layouts of component layers in External Wall Insulation systems (EWI/ETICS)

1.1.1. ATLAS External Wall Insulation System (ETICS) based on elastified polystyrene slabs (EPS)

PDF DWG

 

1.1.2. ATLAS XPS – EWI/ETICS system based on extruded polystyrene slabs

PDF DWG

 

1.1.3. ATLAS ROKER EWI/ETICS system based on mineral wool panels (MW)

PDF DWG

 

1.1.4. ATLAS CERAMIK EWI/ETICS system with ceramic tiles as a finishing layer

PDF DWG

 

1.1.5. ATLAS ROKER G thermal insulation system for underground garages

PDF DWG

 

1.1.6 ATLAS RENOTER EWI/ETICS – renovation on existing insulation

PDF DWG

 

1.1.7 ATLAS GRAWIS EWI/ETICS based on EPS slabs

PDF DWG

 

1.2 External Wall Insulation systems – arrangement of insulation slabs, reinforcing mesh and fasteners

1.2.1. Arrangement of the boards and fixings for EPS and XPS – example

PDF DWG

 

1.2.2. EWI system made with mineral wool panels – insulation slabs layout and fasteners’ fixing pattern – example

PDF DWG

 

1.2.3. EWI system made with lamella mineral wool panels – insulation slabs layout and fasteners’ fixing pattern – example

PDF DWG

 

1.2.4. Arrangement of the reinforcing mesh around the openings

PDF DWG

 

1.2.5. Arrangement of the boards and fixings around the openings

PDF DWG

 

1.2.6. Arrangement of the reinforcing mesh on the external (convex) corner

PDF DWG

 

1.2.7. Arrangement of the reinforcing mesh on the internal (concave) corner

PDF DWG

 

1.3 Thermal Insulation around window reveals

1.3.1. Insulation of the under-reveal wall with the inset window frame with the use of sill profile

PDF DWG

 

1.3.2. Insulation of the under-reveal wall with the inset window frame with the use of corner profile

PDF DWG

 

1.3.3. Insulation of the under-reveal wall with the window frame even to the wall face with the use of sill profile

PDF DWG

 

1.3.4. Insulation of the under-reveal wall with the window frame even to the wall face with a corner profile

PDF DWG

 

1.3.5. Insulation of the under-reveal wall with a ceramic sill

PDF DWG

 

1.3.6. Inset reveal insulated with the use of window profile

PDF DWG

 

1.3.7 Inset reveal insulated with the use of window profile – detail

PDF DWG

 

1.3.8. Lintel insulation with window blind hidden

PDF DWG

 

1.3.9. Lintel insulation with external window blind

PDF DWG

 

1.3.10. ATLAS EWI – precast window sill [UK]

PDF

1.4 Settlement joint, joint of insulated and non-insulated zones, rustications

1.4.1. Settlement joints with the use of expansion joint profile – example

PDF DWG

 

1.4.2. Settlement joints with the use of corner expansion joint profile – example

PDF DWG

 

1.4.3. Joint between wall and ceiling insulation – internal corner

PDF DWG

 

1.4.4. Joint between wall and ceiling insulation – external corner

PDF DWG

 

1.4.5. Rustification with the use of prefabricated trims – example

PDF DWG

 

1.5 Building plinth Insulation

1.5.1. Insulation of wall and plinth – version with the starting track

PDF DWG

 

1.5.2. Insulation of wall and plinth – version with the starting track – detail

PDF DWG

 

1.5.3. A EWI System in Damp-Proof Course Zone – recommended solution

PDF 

 

1.5.3. B EWI System in Damp-Proof Course Zone – admissible solution

PDF 

 

1.6 Insulation by the steep roof and flat roof

1.6.1. Flat roof parapet wall insulation (joint of insulation with existing flat roof insulation)

PDF DWG

 

1.6.2. Joint between wall insulation and steep roof insulation within roof structure – example

PDF DWG

 

1.6.3. Steep roof insulation: horizontal insulation on the last ceiling – example

PDF DWG

 

1.6.4. Insulation of wall over the joining steep roof

PDF DWG

 

1.6.5.A Verge Zone of Pitched Roof Detail – recommended solution

PDF DWG

 

1.6.5.B Verge Zone of Pitched Roof Detail – admissible solution

PDF DWG

 

1.6.6.A ATLAS EWI – verge zone over gable wall – recommended solution [UK]

PDF

 

1.6.6.B ATLAS EWI – verge zone over gable wall – admissible solution [UK]

PDF

 

1.8 External Insulation on frame structure [UK]

1.8.1. ATLAS EWI on steel frame structure [UK]

PDF

 

1.8.2. ATLAS EWI on timber frame [UK]

PDF

 

1.9 External Insulation – sensitive points of the building [UK]

1.9.1. ATLAS EWI around the flue outlet [UK]

PDF

 

1.9.2.A ATLAS EWI around meter box (case A) [UK]

PDF

 

1.9.2.B ATLAS EWI around meter box (case B) [UK]

PDF

 

1.9.2.C ATLAS EWI around meter box (case C) [UK]

PDF